For overseas water purifier brands, a sample that passes its first installation check can still leak after cartridge replacement. Add a post-service leak check to your OEM approval plan so your team can verify the instructions, fittings and cartridge seating before releasing a bulk order.

Qiteng C10 under-sink RO purifier shown as a product example.
Agree on the sample and test conditions
Record the purifier model and revision, cartridge part number, and installation guide version. Ask your supplier to confirm the allowable inlet pressure, water temperature and observation period for that configuration. Use a production-intent cartridge and the tubing and fittings supplied with the sample.
Run the replacement using the customer instructions
Have a technician follow the supplied shutdown, depressurization and replacement steps. Record any step that needed verbal help. Confirm that the instructions show how to identify the correct cartridge position and verify that it is fully seated before restarting the unit.
Observe joints during restart and standby
Dry the area around the cartridge connection and any fittings disturbed during service. Inspect for visible moisture when the supply is restored, while dispensing and again after the agreed standby period. Note the location and timing of any moisture and photograph the first place it appears. If a joint is reseated or a part is replaced, record the change and repeat the check.
Put the acceptance criteria in the purchase specification
Agree on the sample count, test conditions, required records and who can approve corrective action. Ask for an updated instruction sheet when a service step is unclear. When planning an OEM/ODM sample review with Qiteng, share the target market, model and the service conditions your distributors expect.